Anechoic Chamber
HOME >EMC Solution >Anechoic Chamber >Anechoic Chamber(10m Method)
Anechoic Chamber(10m Method)
Features
- Qualified for various registrations (FCC filing, VCCI registration,DAR, NVLAP, A2LA, and NATA authorizations)
- Mainly composed by ferrite radio wave absorber (TFA).Wide-ranged radio wave absorbency is available in combinationwith radio wave matching devices.
- Barrier-free doors allowing for easy transportation of large-sized devices.
- Standard-equipped storage room for amplifiers for the use in the immunity test.
- Applicable to large-sized devices (maximum specification: a turntable of 10 m in diameter/capacity of 20 tons).
- GP-IB controllable attached facilities allowing for automatic instrumentation
in a short time.
- Additional underground pit construction available for installing counter devices especially in the measuring test of communication equipment (optional).
10 Method Anechoic Chamber
10 Method Anechoic Chamber
Standard Specifications
| Type |
ALC-10U |
ALC-10UL |
| Shield inside dimensions (m) |
21.0Lx13.5Wx9.0H |
22.0Lx14.0Wx9.0H |
| Site attenuation characteristic (dB) |
Horizontal/Vertical ±3(at 30MHz to 18GHz) |
Field distribution uniformity characteristic (dB)
(IEC61000-4-3 conforming) |
100(at 150kHz to 1000MHz)
60(at 1GHz to 18GHz) |
Shield
effectiveness (dB)
IEEE-STD 299-1997 |
100(at 150kHz to 1000MHz)
60(at 1GHz to 18GHz) |
Insertion
loss (dB)
(MIL STD-220A conforming)
|
|
| Composit absorber |
Ferrite absorber (TFA) + EM wave absorber
|
| Measuring chamber shield inside dimensions (including an amplifier room) |
|
|
Anechoic chamber(1)
Anechoic chamber(2)
Measuring room(3)
|
|
2.0W×2.0H(Barrier-free structure)
1.0W×2.0H
1.0W×2.0H
|
| Antenna lift |
Lifting range (m)
Lifting speed (sec/m)
|
|
1.0 to 4.0
5 to 25(3-step selection, GP-IB control)
|
| Turntable |
Dimension (m)
Load capacity (kg)
Rotating speed (rpm)
|
|
3.0
1000
1.0 to 4.0
(3-step selection, GP-IB control)
|
5.0
3000
0.5 to 2.0
(3-step selection, GP-IB control)
|
| Attached facilities |
|
| Power supply |
Power supply panel/filter panel/insulating transformer/lighting, etc.
|
|